About 172,000 results
Open links in new tab
  1. electrical - How many amps per leg on a 220V circuit? - Home ...

    May 14, 2018 · 220-240v in the U.S. is 2 legs of a single phase. The 2 legs come off the transformer and have a center tap (the neutral) each leg to neutral is 120v or 240 leg to leg.

  2. Confusion over 220 and 230 volt outlets - Home Improvement …

    Jun 18, 2019 · Rule of thumb for home appliances: 220, 230, 240, it's all close enough not to worry about the difference. There's a good chance the actual voltage on your outlet is …

  3. Sub panel 3 wire and 220Volts - Home Improvement Stack Exchange

    The 2 hots to a 30 amp 220-volt breaker in the sub-panel. The sub-panel would never have 110 volts or anything using a neutral and would not have a neutral bus.

  4. receptacle - What types of electrical outlets are found in a typical ...

    Tricked by a 220 volt outlet hack job How can I figure out why this electrical receptacle is dead? Is it okay to run a switched and unswitched hot on the same neutral? How can I connect a 120V …

  5. How to Switch Power Between 2 Devices Using 1 Power Source

    Dec 23, 2022 · I have a line already which can support up to 25A 2 pole (in breaker panel) I have 2 devices, each rated 220/240V 2-pole. However, at any given time only 1 I need to run.

  6. GFCI Required for 220v outlets? - Home Improvement Stack …

    Nov 12, 2020 · All subsections of the 2014 NEC 210.8(A & B) start off with "All 125v, single phase, 15- and 20-ampere receptacles..." I see no such requirement for 220v …

  7. electrical - Should I use 12/2 or 12/3 to wire a 220V electric ...

    Feb 25, 2016 · When I bought my baseboard heaters, thermostats and 220V breakers I was advised to get 12/3 wire. When I attempted to install the heaters I found that the thermostats, …

  8. Can I extend a 240 V line? - Home Improvement Stack Exchange

    Jan 1, 2020 · I have a 240 V line in my kitchen for an oven. We are remodeling the kitchen and moving the oven and, thus, need to move the 240 V outlet. Can I extend the line by joining …

  9. 20 amp, 220v, 2 pole GFCI Breaker - Home Improvement Stack …

    Apr 17, 2020 · Do I need a neutral white wire to install a 220v GFCI breaker in the main panel ? Currently have 220v, 2 pole red hot, black hot and green ground in the circuit running pool …

  10. What size wire for 20 amp 220V 80' - Home Improvement Stack …

    Jun 26, 2018 · I am running an electrical line for an a/c unit 220 it calls for 20 amp breaker about 15' underground and the rest overhead in conduit 80' total. My question is what size wire …