About 136,000 results
Open links in new tab
  1. what can I do if Cheater Air Admittance Valves are not allowed?

    Apr 16, 2018 · AAV's are prohibited in the Uniform Plumbing Code, It is not that the UPC specifically prohibits AAV's. It is a default position that AAV's are not an approved product …

  2. Is there any way to test an Air Admittance Vent?

    Nov 13, 2020 · FWIW, It seems as if the AAV are very effective at sealing under pressure, which is what the tests I just made using the tips above seemed to indicate, but the function I really …

  3. Washing Machine + Slop Sink + AAV - Love Plumbing & Remodel

    Apr 5, 2012 · The AAV is a one way valve letting air in to prevent siphonage, which BOTH traps need and your AAV will provide. The positive pressure situation occurs if the discharge is …

  4. Replacing an Automatic Air Vent - Love Plumbing & Remodel

    Jan 4, 2025 · The AAV is equipped with a float located internally, which is utilized to open/close a bleeder valve. The float will not 'float' when the chamber contains air, so the bleeder valve will …

  5. Kitchen S trap to P Trap and AAV set up help.

    May 22, 2025 · Hi, My sink has been plumbed with an S Trap since I remodeled In 2010, I get gurgling when dishwasher runs and sometimes sink drains slow ( speeds up if I manually open …

  6. 2 Air Admittance Valves on double sink, IPC 2009

    Jun 25, 2010 · Hey All, My local inspector allowed me to use AAVs on my kitchen double sink, as there was no good way to hard vent it. He said that a double wye with an AAV off the top was …

  7. Need advice on air admittance valve replacement

    Sep 8, 2022 · Additional question. The AAV has a 20 DFU stamped on it. However, at Menards, Will this replacement unit from Menards WORK (says 20 DFU Branch/8 DFU Stack? I have no …

  8. Basement Bathroom Wet Vent + AAV - Love Plumbing & Remodel

    Mar 18, 2024 · DIY plumbing a basement bathroom in Michigan (IPC) and am wondering about venting. Only real access to existing stack is a 3" line that carries waste from other bathrooms …

  9. Distance to air gap drain. - Love Plumbing & Remodel

    Jan 24, 2025 · Yes for the IPC, although that requires you to get the exact slope of 1/4" per foot. Slope it more, you reduce the maximum horizontal. No for the UPC, as it further imposes a …

  10. Laundry room drains - washer and sink on same drain with AAV

    Nov 20, 2022 · The bathroom downsteam will be vented temporarily with an aav, and then when renovations are continued next year on the upstairs bathroom, venting will be tied into the …